玩弄人妻少妇1000系列,放荡的少妇2做爰,精品人妻一区二区三区久久夜夜嗨,亚洲人妻性爱

產(chǎn)品中心/ products

您的位置:首頁  -  產(chǎn)品中心  -    -  質(zhì)控模體  -  CIRS 603A頭部模體

CIRS 603A頭部模體

  • 產(chǎn)品型號:
  • 更新時間:2024-07-30

簡要描述:CIRS 603A頭部模體由可用X射線,計算機斷層掃描和磁共振成像技術成像的材料制成。它能很好地描述迄今為止所有測試的MRI序列,包括T1加權,T2加權,3D飛行時間,MPRAGE和CISS序列。

產(chǎn)品詳情
品牌其他品牌產(chǎn)地進口
產(chǎn)品新舊全新


CIRS 603A頭部模體由可用X射線,計算機斷層掃描和磁共振成像技術成像的材料制成。它能很好地描述迄今為止所有測試的MRI序列,包括T1加權,T2加權,3D飛行時間,MPRAGE和CISS序列。

頭骨是由塑料基組織替代品制造的,而間質(zhì)和周圍的軟組織是由專有的水基聚合物制成的。整個模型裝在一個清晰的真空成型塑料外殼中,以防止凝膠干燥。

顱骨體的整個顱骨部分填充有間距為1.5cm的3mm直徑桿的正交三維網(wǎng)格。五個擴展的軸桿在網(wǎng)格的參考原點相交。每個擴展軸的末端都配有CT和MR標記,可以準確對準激光以及圖像配準。

包括一個6.35毫米直徑的丙烯酸棒,每個耳道有一個3毫米直徑和17毫米長的空氣空隙。


特點和好處
T1,T2和3D TOF MRI采集的圖像良好
CT掃描的圖像很好
與立體定向框架一起使用的保護墊
圖像可以導入立體定位程序
CT掃描可以用來評估MRI的準確性
包括的材料
3D擬人頭骨幽靈
ABS真空成型搖籃
5立體框架墊
定制攜帶案例
用戶指南
保修信息
4年保修

CIRS 603A頭部模體

CIRS 603A頭部模體
CIRS 603A頭部模體

CIRS 603A頭部模體


CIRS 603A was designed for assessment of MR image distortion in Stereotactic Radiosurgery Planning.  It is also a useful tool for verifying image fusion and deformable image registration algorithms used in various treatment planning systems.  The tissue equivalent, anthropomorphic design provides the closest conditions to a clinical imaging scenario.  The phantom can be imaged using X-ray, Computed Tomography and Magnetic Resonance.  It images well with all MRI sequences tested to date, including T1 weighted, T2 weighted, 3D Time of Flight, MPRAGE and CISS.

The skull is manufactured from a plastic-based bone substitute, and the interstitial and surrounding soft tissues are made from a proprietary signal generating water-based polymer. The entire phantom is encased in a clear plastic shell to protect gel from desiccation. The phantom is supplied with specially designed pads that allow fixation with any stereotactic frame or mounting for end-to-end testing. The phantom is also suitable for frameless SRS QA.

The entire inter-cranial portion of the skull volume is filled with an orthogonal 3D grid of 3mm diameter rods spaced 15 mm apart. Five extended axis-rods intersect at the reference origin of the grid. The end of each extended axis is fitted with CT/MR markers allowing for accurate positioning with lasers and co-registration of CT and MR image sets.  

The phantom includes right and left air voids, 3 mm in diameter by 17 mm long to simulate each ear canal for evaluation of potential distortions commonly found in clinical settings.

To accommodate image fusion techniques, CIRS can offer value added services such as phantom specific CMM, reference CT or MRI data sets, attachment of customer specific registration devices and inclusion of special point markers.

Features:

Images well on T1, T2 and 3D TOF MRI acquisitions

Images well on CT scans

Protective pad for use with Stereotactic Frame

Images can be imported into stereotactic localization program

CT scans can be used to assess MRI accuracy

CIRS 603A頭部MRI模體實物拍攝照片:

CIRS 603A頭部模體

CIRS 603A頭部模體

CIRS 603A頭部模體

     


在線咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯數(shù)字),如:三加四=7
產(chǎn)品中心
質(zhì)控模體

CONTACT

辦公地址:深圳市龍崗區(qū)南灣街道沙平北路111號吉茂大廈608A

TEL:0755-28896837

EMAIL:szchina1718@163.com
掃碼加微信
版權所有©2024 深圳為爾康科技有限公司 All Rights Reserved   備案號:粵ICP備17126621號   sitemap.xml 技術支持:制藥網(wǎng)   管理登陸

TEL:13632925349

掃碼加微信